← CVE catalog

CVE-2026-112354

Critical CVSS 9.8

Published 2026-11-03 ยท last changed 2026-11-03

The fix

We hold no Microsoft remediation data for CVE-2026-112354, which normally means it is not a Windows CVE. For non-Microsoft software the fix is the vendor's own updated release, and the affected versions are listed below.

What it is

Etrel INCH AC charging station management web interface prior to firmware versions 7.1.2 and 8.0.1 contains a hard-coded default credentials vulnerability that allows remote attackers to gain full Administrator access by authenticating with the factory-default account. Attackers can log in over cleartext HTTP to obtain complete charger configuration, OCPP ChargePoint Identity, and CSMS WebSocket connection details, enabling unauthorized administrative control of the charging station.

Sources

CVSS vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H