Client: Enable Max Offline Users
Computer Configuration > Administrative Templates > Duo Authentication for Windows Logon > Client Settings
OfflineMaxUsers DuoWindowsLogon.admx Duo Windows Logon 6.0.1 Registry
| Key (computer) | HKEY_LOCAL_MACHINE\SOFTWARE\Policies\Duo Security\DuoCredProv |
|---|---|
| Value name | none on the policy itself; the options below write their own values |
| Supported on | At least Windows Server 2003 operating systems or Windows XP Professional |
| Namespace | logon.windows.duosecurity.com |
Options
Option Value written Type and range Default Enter the maximum number of Offline Users: OfflineMaxUsers REG_DWORD, 1 to 50 5
What each state writes
Computed with the same rules RFF Conformance uses, with the default options. Pick your own options in the builder below.
HKLM\SOFTWARE\Policies\Duo Security\DuoCredProv | OfflineMaxUsers | 5 REG_DWORD |
HKLM\SOFTWARE\Policies\Duo Security\DuoCredProv | OfflineMaxUsers | value removed |
HKLM\SOFTWARE\Policies\Duo Security\DuoCredProv | OfflineMaxUsers | value removed |
In Intune
Intune sets third-party templates by importing the ADMX first. In the admin center that is Devices > Configuration > Import ADMX, then a profile from Imported Administrative templates. With a custom (OMA-URI) profile instead, ingest the file once and then set the policy:
| 1. Ingest the ADMX | ./Device/Vendor/MSFT/Policy/ConfigOperations/ADMXInstall/DuoWindowsLogon/Policy/DuoWindowsLogon String value: the whole contents of DuoWindowsLogon.admx. "DuoWindowsLogon" is a name you choose; use the same one below. |
|---|---|
| 2. Set it (device) | ./Device/Vendor/MSFT/Policy/Config/DuoWindowsLogon~Policy~Duo~Client/OfflineMaxUsers |
| Value to enable | <enabled/><data id="OfflineMaxUsers_DecTextBox" value="5"/> |
| Value to disable | <disabled/> |
Path format from Microsoft's ADMX ingestion documentation; the category part comes from this ADMX.
Build it
Choose a state and options. You get the exact writes, a .reg file, a script that applies them, and a script that checks a machine and reports drift. Nothing leaves your browser.
Keep it set across your fleet
Group Policy writes these values once per refresh and never tells you when something changes them back. RFF Conformance reads them from every computer, shows which ones drifted and who changed them, and puts them back on approval, with each change versioned and undoable. It works without a domain controller.
Source: Duo Authentication for Windows Logon policy templates, version 6.0.1, published by Cisco Duo 2026-11-03. Policy names and option labels are Cisco Duo's.
ADMX Viewer is open source: github.com/deadarcher/AdmxViewer. Found a wrong registry value, a missing catalog, or a template that won't load? Open an issue, email brian@getrff.com, or use the form below.
Your note and the summary below are all that get sent. Your file stays on your machine.