ADMX Viewer →

Configure Logging

Computer Configuration > Administrative Templates > Base Image Script Framework (BIS-F) > Global

Computer Policy name POL_LogCfg BaseImageScriptFramework.admx BIS-F 7.1912.7

Registry

Key (computer)HKEY_LOCAL_MACHINE\SOFTWARE\Policies\Login Consultants\BISF
Value nameLIC_BISF_POL_LogCfg
Supported onAt least Windows Vista
NamespaceFullArmor.Policies.8792664D_EBD1_45F9_815F_65014D0224E7

Options

OptionValue writtenType and rangeDefault
Enable Central Log Share LIC_BISF_CLI_LSb
SOFTWARE\Policies\Login Consultants\BISF
on / off none
Log Share LIC_BISF_CLI_LS
SOFTWARE\Policies\Login Consultants\BISF
REG_SZ \\Server\Share
Log Retention LIC_BISF_CLI_LF_RT
SOFTWARE\Policies\Login Consultants\BISF
REG_DWORD, ... to 20 5
SCCM / MDT Logfile Redirection LIC_BISF_CLI_TSLogRedirection
SOFTWARE\Policies\Login Consultants\BISF
on / off none
Enable Windows Powershell Transcript LIC_BISF_CLI_LOG_WPT
SOFTWARE\Policies\Login Consultants\BISF
on / off none

What each state writes

Computed with the same rules RFF Conformance uses, with the default options. Pick your own options in the builder below.

Enabled
HKLM\SOFTWARE\Policies\Login Consultants\BISF LIC_BISF_POL_LogCfg 1 REG_DWORD
HKLM\SOFTWARE\Policies\Login Consultants\BISF LIC_BISF_CLI_LogCfg YES REG_SZ
HKLM\SOFTWARE\Policies\Login Consultants\BISF LIC_BISF_CLI_LS \\Server\Share REG_SZ
HKLM\SOFTWARE\Policies\Login Consultants\BISF LIC_BISF_CLI_LF_RT 5 REG_DWORD
Disabled
HKLM\SOFTWARE\Policies\Login Consultants\BISF LIC_BISF_POL_LogCfg value removed
HKLM\SOFTWARE\Policies\Login Consultants\BISF LIC_BISF_CLI_LogCfg NO REG_SZ
HKLM\SOFTWARE\Policies\Login Consultants\BISF LIC_BISF_CLI_LSb value removed
HKLM\SOFTWARE\Policies\Login Consultants\BISF LIC_BISF_CLI_LS value removed
HKLM\SOFTWARE\Policies\Login Consultants\BISF LIC_BISF_CLI_LF_RT value removed
HKLM\SOFTWARE\Policies\Login Consultants\BISF LIC_BISF_CLI_TSLogRedirection value removed
HKLM\SOFTWARE\Policies\Login Consultants\BISF LIC_BISF_CLI_LOG_WPT value removed
Not configured
HKLM\SOFTWARE\Policies\Login Consultants\BISF LIC_BISF_POL_LogCfg value removed
HKLM\SOFTWARE\Policies\Login Consultants\BISF LIC_BISF_CLI_LogCfg value removed
HKLM\SOFTWARE\Policies\Login Consultants\BISF LIC_BISF_CLI_LSb value removed
HKLM\SOFTWARE\Policies\Login Consultants\BISF LIC_BISF_CLI_LS value removed
HKLM\SOFTWARE\Policies\Login Consultants\BISF LIC_BISF_CLI_LF_RT value removed
HKLM\SOFTWARE\Policies\Login Consultants\BISF LIC_BISF_CLI_TSLogRedirection value removed
HKLM\SOFTWARE\Policies\Login Consultants\BISF LIC_BISF_CLI_LOG_WPT value removed

In Intune

Intune sets third-party templates by importing the ADMX first. In the admin center that is Devices > Configuration > Import ADMX, then a profile from Imported Administrative templates. With a custom (OMA-URI) profile instead, ingest the file once and then set the policy:

1. Ingest the ADMX./Device/Vendor/MSFT/Policy/ConfigOperations/ADMXInstall/BISF/Policy/BaseImageScriptFramework
String value: the whole contents of BaseImageScriptFramework.admx. "BISF" is a name you choose; use the same one below.
2. Set it (device)./Device/Vendor/MSFT/Policy/Config/BISF~Policy~CAT_BISF~CAT_Global/POL_LogCfg
Value to enable<enabled/><data id="CHK_CLI_LogCfg" value="true"/><data id="TXT_LogCfg" value="\\Server\Share"/><data id="DXT_LogRetention" value="5"/><data id="CHK_CLI_TSLogRedirection" value="true"/><data id="CHK_LOG_WPT" value="true"/>
Value to disable<disabled/>

Path format from Microsoft's ADMX ingestion documentation; the category part comes from this ADMX.

Build it

Choose a state and options. You get the exact writes, a .reg file, a script that applies them, and a script that checks a machine and reports drift. Nothing leaves your browser.

Keep it set across your fleet

Group Policy writes these values once per refresh and never tells you when something changes them back. RFF Conformance reads them from every computer, shows which ones drifted and who changed them, and puts them back on approval, with each change versioned and undoable. It works without a domain controller.

How Conformance works · Your baseline from this site

Source: Base Image Script Framework (BIS-F) policy templates, version 7.1912.7, published by EUCweb (open source) 2022-11-21. Policy names and option labels are EUCweb (open source)'s.

ADMX Viewer is open source: github.com/deadarcher/AdmxViewer. Found a wrong registry value, a missing catalog, or a template that won't load? Open an issue, email brian@getrff.com, or use the form below.